LOINC codes say what was measured, on what specimen, in what quantity
Reviewed by Gerard Stanley Jr., M.D., Chief Medical Officer, in the review of the back catalog on . The text was updated on , after this review. What this review is
LOINC version 2.83, released 19 August 2026, lists 112,405 concepts. The certification rule at 45 CFR 170.207 names version 2.72 from 16 February 2022, and also version 2.52. A 2010 review of 884 mappings found 4 tests on an unrelated code and 36 with an error on at least one axis.
LOINC is Regenstrief's code system for laboratory and clinical observations. Version 2.83, released on 19 August 2026, lists 112,405 concepts on loinc.org. The federal vocabulary rule still names older versions. A 2010 review of voluntary mappings did not find a single failure rate of 6 to 19 percent. It counted errors in a sample.
LOINC is the code system for lab and clinical observations
LOINC is Regenstrief's code system for laboratory and clinical observations. A LOINC code says what was measured, on what specimen, and in what kind of quantity. Version 2.83, released on 19 August 2026, lists 112,405 concepts on loinc.org. The federal vocabulary rule at 45 CFR 170.207(c) still names older versions, 2.72 and 2.52. A record that does not say which version it was mapped to cannot be checked against either one. SuperTruth's DTI Engine scores a record on eight dimensions of trust before a model acts on it.
How many concepts the current release lists
The LOINC homepage, read 24 November 2026, says version 2.83 was released on 19 August 2026 and gives these counts. The next release on that page is February 2027. Source: LOINC.
| What version 2.83 lists | Count |
|---|---|
| New concepts in v2.83 | 3,080 |
| Total concepts | 112,405 |
| Laboratory | 69,651 |
| Clinical | 28,786 |
| Surveys | 12,807 |
| Claims attachments | 1,161 |
The homepage does not say that 112,405 is the count of active laboratory tests at one hospital. It is the release's concept count, split as in the table.
The version the certification rule names
The vocabulary standard at 45 CFR 170.207(c) adopts two LOINC standards. Paragraph (c)(1) names "Logical Observation Identifiers Names and Codes (LOINC) Database Version 2.72", produced by the Regenstrief Institute, "February 16, 2022". Paragraph (c)(3) names LOINC Database version 2.52 for laboratory and clinical observations. The eCFR page displayed those sentences as of 19 November 2026. The same page links an amendment at 91 FR 67992, 28 October 2026. This post cites the sentences on the page. It does not describe the amendment.
Version 2.83 on the LOINC site and version 2.72 in paragraph (c)(1) are not the same release. A file can be coded with a LOINC version the certification standard does not name. That is a version fact. It is not, by itself, a wrong result.
What one mapping study actually counted
Lin, Vreeman, McDonald, and Huff, in a 2010 symposium paper, reviewed voluntary mappings from ARUP, Intermountain, and Regenstrief. The abstract says: "We received 9,027 laboratory tests mapped to 3,669 unique LOINC codes. A one tenth sample (884 tests) was manually reviewed for correctness of the mappings. After review, there were 4 tests mapped to totally unrelated LOINC codes and there were 36 tests containing at least one error in mapping to the 6 axes of LOINC." The paper calls the LOINC release then current version 2.30, dated 26 February 2010, and says that release contained 57,693 active codes. That 2010 sentence is not the 2026 concept count above. Source: Correctness of Voluntary LOINC Mapping for Laboratory Tests in Three Large Institutions (Lin et al., 2010).
| What the 2010 abstract states | Count |
|---|---|
| Laboratory tests received | 9,027 |
| Unique LOINC codes those tests mapped to | 3,669 |
| Tests in the reviewed sample | 884 |
| Sample tests mapped to an unrelated code | 4 |
| Sample tests with an error on at least one of the six axes | 36 |
The abstract does not publish a percent. This post does not turn those counts into one. The same abstract does not say that 6 to 19 percent of laboratory tests cannot be mapped. That range was in an earlier draft of this page. It is not the result of the study opened here.
The paper's sample is three institutions, voluntary mappings, and a tenth of the file, reviewed by hand. It is not a current national rate.
What the code is for
A LOINC code is meant to say what was measured, on what specimen, in what kind of quantity. The 2010 paper treats errors on the six axes as mapping errors, including a more specific local test mapped to a more general code. This post does not rename the axes beyond that paper's "6 axes," because the homepage opened here does not print the six names.
A model that treats the code as the identity of the result will treat a wrong axis as a different test. The 2010 sample is the evidence this post has for how often that happened in those three files. It is not a license to apply 36 out of 884 to a health system that was not in the study.
Where the index uses a weight
SuperTruth's Data Trust Index uses eight weights: Provenance 25, Consent 20, Recency 15, Quality 10, Concordance 10, Validation 10, Breadth 5, and Stability 5. These are shares of the index. They are not LOINC axis scores, and they are not the 2010 error counts.
| Dimension | Weight |
|---|---|
| Provenance | 25 |
| Consent | 20 |
| Recency | 15 |
| Quality | 10 |
| Concordance | 10 |
| Validation | 10 |
| Breadth | 5 |
| Stability | 5 |
The weights are percents of the index. They add to 100.
Provenance, at 25 percent of the index, is the weight that asks which LOINC version was used and when the local code was mapped. The certification rule names version 2.72 as of the sentence quoted above. The public release on 19 August 2026 is version 2.83. A record that does not say which version it was mapped to cannot be checked against either one.
The index does not award points for using LOINC. A code can be present and still be one of the 36 sample tests with an axis error. Consent, recency, and the other weights are separate questions. The 2010 paper does not score them.
If your team is training on laboratory results and needs the mapping version on the record before the model treats the code as the test, schedule a conversation or call (215) 918-4140.
Further reading:
- DTI Engine
- Health systems solution
- SNOMED CT mapping trust: when clinical terminology becomes a liability
- HL7 message quality scoring: what trust looks like for legacy EHR data
- CPT code integrity: what claims data quality means for AI model accuracy
Sources
- Regenstrief Institute, LOINC homepage, version 2.83 released 19 August 2026, read 24 November 2026: https://loinc.org/
- eCFR, 45 CFR 170.207, vocabulary standards, displayed as of 19 November 2026: https://www.ecfr.gov/current/title-45/subtitle-A/subchapter-D/part-170/subpart-B/section-170.207
- Lin MC, Vreeman DJ, McDonald CJ, Huff SM. Correctness of Voluntary LOINC Mapping for Laboratory Tests in Three Large Institutions. AMIA Annual Symposium Proceedings. 2010. https://pmc.ncbi.nlm.nih.gov/articles/PMC3041457/
Reviewed by Gerard Stanley Jr., M.D., Chief Medical Officer, in the review of the back catalog on . The text was updated on , after this review. What this review is

Jason Alan Snyder
Co-founder of SuperTruth and Artists & Robots, and an inventor on the Data Trust Index patents. Twenty-plus years building technology inside Interpublic Group. He writes here nearly every day on data trust, provenance, and what AI should be allowed to act on, and publishes essays on his Substack.
See it in practice
DTI scores the record, not the patient.
8 dimensions. 0 to 100. Travels with every record permanently.